Thesis Diseño de proceso de captura desde el aire (DAC) de dióxido de carbono con metales pesados para la zona norte de Chile
No Thumbnail Available
Date
2026-10
Journal Title
Journal ISSN
Volume Title
Program
Ingeniería Civil Química
Campus
Campus Santiago San Joaquín
Abstract
Se evaluó técnica y económicamente, a nivel conceptual, la captura directa de CO2 desde el aire en El Loa (77,3 kPa, 13 a 17 °C y humedad relativa de 11 a 36%), donde el aire contiene 0,84 a 0,97 µg/m3 de As2O3 emitido por la División Chuquicamata. Se modeló un proceso de adsorción con ciclo de temperatura y vacío (TVSA) en lechos de 1,5 m para capturar 1.000 t CO2/año, con carbón activado GCA-1240 y zeolita 13X. A la presión parcial del CO2 en el aire, la 13X adsorbe 0,32 mol/kg y el carbón 9,9×10−4 mol/kg. Por ello el carbón, regenerado a 50 °C y 5.500 Pa, entrega un producto con 1,5% de CO2 y consume unos 350 kWh/kgCO2 térmicos, y no es apto. La 13X, a 0,95 m/s, con adsorción de 5 h y regeneración a 250 °C y 3.000 Pa con purga de N2, produce ≈1.020 t CO2/año con 84 a 88% de pureza en base seca y consume 33,1 kWh/kgCO2 (119 GJ/t). El soplador aporta el 59% de esa energía, por la caída de presión de 20 kPa del lecho, y el calentamiento el 37%. Con electricidad a 0,0238 USD/kWh, tasa de 12% y 20 años, el costo nivelado de captura es de ≈6.500 USD/t (P10 a P90 de 5.400 a 9.300 USD/t), en un 87% capital y mantención. El arsénico no resultó limitante, ya que eleva la caída de presión en menos de un 0,5% en cinco años, aunque queda abierta su sublimación durante la regeneración. La humedad, en cambio, condiciona el proceso. En la 13X no reduce la producción, pero se desorben de 2 a 9 kg de agua por kilogramo de CO2, lo que eleva el consumo térmico en un 70%. El proceso es factible a nivel conceptual, pero no competitivo, porque su energía y su costo superan en un orden de magnitud a los de la literatura. Mejorarlo exige un contactor de menor caída de presión, gestionar el agua y validar experimentalmente el modelo y el comportamiento del arsénico.
A conceptual-level techno-economic assessment of direct air capture of CO2 was carried out for El Loa, Chile (77.3 kPa, 13 to 17 °C and 11 to 36 % relative humidity), where the air contains 0.84 to 0.97 μg/m3 of As2O3 emitted by the Chuquicamata copper smelter. A temperature and vacuum swing adsorption (TVSA) process with 1.5 m beds was modelled to capture 1,000 t CO2/year, using activated carbon GCA-1240 and zeolite 13X. At the CO2 partial pressure of air, 13X adsorbs 0.32 mol/kg and the carbon 9.9 × 10−4 mol/kg. Hence the carbon, regenerated at 50 °C and 5,500 Pa, delivers a product with 1.5 % CO2 and consumes about 350 kWh/kgCO2 of heat, so it is not suitable. Zeolite 13X, at 0.95 m/s, with 5 h adsorption and regeneration at 250 °C and 3,000 Pa with N2 purge, produces about 1,020 t CO2/year with 84 to 88 % purity on a dry basis and consumes 33.1 kWh/kgCO2 (119 GJ/t). The blower accounts for 59 % of this energy, due to the 20 kPa pressure drop of the bed, and heating for 37 %. With electricity at 0.0238 USD/kWh, a 12 % discount rate and 20 years, the levelised cost of capture is about 6,500 USD/t (P10 to P90 of 5,400 to 9,300 USD/t), 87 % of it capital and maintenance. Arsenic was not a limiting factor, since it raises the pressure drop by less than 0.5 % over five years, although its sublimation during regeneration remains an open question. Humidity, in contrast, governs the process. In 13X it does not reduce production, but 2 to 9 kg of water are desorbed per kilogram of CO2, which raises the thermal consumption by 70 %. The process is feasible at a conceptual level but not competitive, because its energy use and cost are an order of magnitude above those reported in the literature. Improving it requires a contactor with a lower pressure drop, water management, and experimental validation of the model and of the behaviour of arsenic.
A conceptual-level techno-economic assessment of direct air capture of CO2 was carried out for El Loa, Chile (77.3 kPa, 13 to 17 °C and 11 to 36 % relative humidity), where the air contains 0.84 to 0.97 μg/m3 of As2O3 emitted by the Chuquicamata copper smelter. A temperature and vacuum swing adsorption (TVSA) process with 1.5 m beds was modelled to capture 1,000 t CO2/year, using activated carbon GCA-1240 and zeolite 13X. At the CO2 partial pressure of air, 13X adsorbs 0.32 mol/kg and the carbon 9.9 × 10−4 mol/kg. Hence the carbon, regenerated at 50 °C and 5,500 Pa, delivers a product with 1.5 % CO2 and consumes about 350 kWh/kgCO2 of heat, so it is not suitable. Zeolite 13X, at 0.95 m/s, with 5 h adsorption and regeneration at 250 °C and 3,000 Pa with N2 purge, produces about 1,020 t CO2/year with 84 to 88 % purity on a dry basis and consumes 33.1 kWh/kgCO2 (119 GJ/t). The blower accounts for 59 % of this energy, due to the 20 kPa pressure drop of the bed, and heating for 37 %. With electricity at 0.0238 USD/kWh, a 12 % discount rate and 20 years, the levelised cost of capture is about 6,500 USD/t (P10 to P90 of 5,400 to 9,300 USD/t), 87 % of it capital and maintenance. Arsenic was not a limiting factor, since it raises the pressure drop by less than 0.5 % over five years, although its sublimation during regeneration remains an open question. Humidity, in contrast, governs the process. In 13X it does not reduce production, but 2 to 9 kg of water are desorbed per kilogram of CO2, which raises the thermal consumption by 70 %. The process is feasible at a conceptual level but not competitive, because its energy use and cost are an order of magnitude above those reported in the literature. Improving it requires a contactor with a lower pressure drop, water management, and experimental validation of the model and of the behaviour of arsenic.
Description
Keywords
Captura directa de aire, Procesos de separación de gases, Adsorción física, Regeneración térmica, Eficiencia energética, Contaminación por arsénico, Tecnologías de mitigación del cambio climático