Estimados(as), Las Tesis no se revisarán, ni publicarán desde el día 23 de enero hasta el día 23 de febrero por periodo de vacaciones.
 

Thesis
ESTUDIO DE FACTIBILIDAD TÉCNICA DE LA RECUPERACIÓN DE SOLVENTES A PARTIR DE LAS NAFTAS OBTENIDAS EN EL PROCESO DE REFINACIÓN DE ACEITE LUBRICANTE USADO

dc.contributor.departmentUniversidad Tecnica Federico Santa Maria UTFSM INGENIERÍA QUíMICA Y AMBIENTAL
dc.contributor.guiaRAMIREZ LIVINGSTON, DANIEL ALBERTO
dc.contributor.otherARZE CONTRERAS, MARIO FELIPE
dc.coverage.spatialCampus Casa Central Valparaíso
dc.creatorRojas Gálvez, Cristian Eduardo
dc.date.accessioned2024-11-02T02:30:04Z
dc.date.available2024-11-02T02:30:04Z
dc.date.issued2016
dc.descriptionCatalogado desde la version PDF de la tesis.es_CL
dc.description.abstractEn BIOFACTOR se procesa aceite lubricante usado, este contiene un 4% de nafta (estimado). Esta nafta se caracteriza utilizando un ensayo de destilación atmosférico (ASTM D86). Mediante el ensayo se determino que la nafta contiene entre un 30 – 35% de solventes. Estos solventes son aguarrás mineral y gasolina blanca, utilizados principalmente como diluyentes para pintura y removedores de manchas.El proceso diseñado consiste en una columna de destilación que es operada en dos etapas. En la etapa 1 se procesa la nafta BIOFACTOR, recuperando la gasolina blanca y obteniendo un producto intermedio. El producto intermedio es procesado en la etapa 2, se recupera el aguarrás mineral y el gasoil.La columna diseñada es una torre empacada, tiene 30 etapas equivalentes a una altura de relleno de 30 ft (9.15 m) y un diámetro de 1 ft (0.30 m).La planta de recuperación de solventes es capaz de procesar 360,000 galones de nafta mensuales a una razón de 500 gal/h. En BIOFACTOR hay disponibles mensualmente 7,200 galones de nafta, al ser procesados se estima que se recuperan entre 1,080 – 1650 galones de gasolina blanca y 860 – 1,080 galones de aguarrás mineral.La inversión total estimada es de 567,621.39 US$.es_CL
dc.description.abstractIn BIOFACTOR used lubricating oil is processed, this one contains 4% of (estimated) naphtha. This naphtha is characterized using an atmospheric distillation test (ASTM D86). The test determined that the naphtha contained between 30 - 35% of solvents. These solvents are mineral spirit and VM&P Naphtha (Varnish Makers and Painter), used mainly as paint thinners and stain removers.The designed process consists of a distillation column that is operated in two stages. In stage 1 the BIOFACTOR naphtha is processed, recovering the VM&P Naphtha and obtaining an intermediate product. The intermediate product is processed in step 2, white spirit and gasoil are recovered.The column designed is a packed tower, has 30 stages equivalent to a packed height of 30 ft (9.15 m) and a diameter of 1 ft (0.30 m).The solvent recovery plant is capable of processing 360,000 gallons of naphtha per month at a rate of 500 gal/h. In BIOFACTOR there are available 7,200 gallons of naphtha per month, to be processed it is estimated that they recover between 1,080 – 1650 gallons of VM&P Naphtha and 860 – 1,080 gallons of white spirit.The estimated total investment is 567,621.39 US$.eng
dc.description.degreeINGENIERO CIVIL QUÍMICO
dc.format.mediumCD ROM
dc.identifier.barcode3560900232383
dc.identifier.urihttps://repositorio.usm.cl/handle/123456789/71019
dc.rights.accessRightsB - Solamente disponible para consulta en sala (opción por defecto)
dc.subjectACEITE LUBRICANTE USADO
dc.subjectNAFTAS
dc.subjectRECUPERACION DE SOLVENTES
dc.subjectREFINACION DE ACEITE
dc.titleESTUDIO DE FACTIBILIDAD TÉCNICA DE LA RECUPERACIÓN DE SOLVENTES A PARTIR DE LAS NAFTAS OBTENIDAS EN EL PROCESO DE REFINACIÓN DE ACEITE LUBRICANTE USADO
dc.typeTesis de Pregrado
dspace.entity.typeTesis
usm.date.thesisregistration2016
usm.identifier.thesis4500013811

Files

Original bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
3560900232383UTFSM.pdf
Size:
3.33 MB
Format:
Adobe Portable Document Format