EL REPOSITORIO SE ENCUENTRA EN MARCHA BLANCA

 

Thesis
ESTUDIO DE CAUSAS DE FALLA DE CONMUTACIÓN EN CICLOCONVERSORES QUE ALIMENTAN UN MOTOR ANILLO EMPLEADO EN MOLINOS GEARLESS

dc.contributor.advisorPONTT OLIVARES, JORGE ANTONIO
dc.contributor.authorCID REYES, PATRICIO ARMANDO
dc.contributor.departmentUniversidad Técnica Federico Santa María. Departamento de Electrónicaes_CL
dc.contributor.otherOLIVARES SALINAS, MANUEL ANTONIO
dc.coverage.spatialCasa Central Valparaísoes_CL
dc.date.accessioned2024-10-31T12:03:19Z
dc.date.available2024-10-31T12:03:19Z
dc.date.issued2019
dc.description.abstractEn aplicaciones industriales como plantas concentradoras mineras se emplean accionamientos con máquinas sincrónicas alimentadas por cicloconversores de alta potencia, alcanzando hoy en día 28 MW. La gestión productiva se ve perjudicada ante fallas inesperadas de estos sistemas de accionamiento, lo que plantea la necesidad de mejorar el tratamiento de fallas. En este marco, este trabajo busca identificar, entender y documentar de manera simple una falla de conmutación para un cicloconvertidor trifásico de configuración típica de 6 y 12 pulsos. Para este fin, se hace la descripción y análisis para las causas probables de falla consistentes, por ejemplo, en la combinación de ajustes, parametrización del sistema de control junto con defectos en algún componente. Este trabajo contribuye con una guía para el mantenimiento especializado, con menores tiempos asociados de detección y aclaramiento de la falla, permitiendo mejorar la gestión productiva con impacto en la disponibilidad y productividad de la planta industrial.es_CL
dc.description.abstractIn industrial applications such as mining concentrator plants, drives with synchronous machines fed by high-power cycloconverters are used, reaching 28 MW today. Productive management is adversely affected by unexpected failures of these drive systems, which raises the need to improve fault handling. In this context, this work seeks to identify, understand and document in a simple way a switching fault for a three phase cycleconverter with a typical configuration of 6 and 12 pulses. For this purpose, the description and analysis are made for probable causes of failure consistent, for example, in the combination of adjustments, parameterization of the control system together with defects in some component. This work contributes with a guide for the specialized maintenance, with smaller associated times of detection and clarification of the fault, allowing to improve the productive management with impact in the availability and productivity of the industrial plant.en
dc.description.degreeINGENIERO CIVIL ELECTRÓNICOes_CL
dc.description.programINGENIERÍA CIVIL ELECTRÓNICAes_CL
dc.identifier.barcode3560900260892es_CL
dc.identifier.urihttps://repositorio.usm.cl/handle/123456789/65901
dc.subjectCICLOCONVERSORESes_CL
dc.subjectMOTOR ANILLOes_CL
dc.subjectMOLINOS GEARLESSes_CL
dc.subjectFALLA DE CONMUTACIONes_CL
dc.titleESTUDIO DE CAUSAS DE FALLA DE CONMUTACIÓN EN CICLOCONVERSORES QUE ALIMENTAN UN MOTOR ANILLO EMPLEADO EN MOLINOS GEARLESSes_CL
dc.typeTesis de Pregrado
dspace.entity.typeTesis

Files

Original bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
3560900260892UTFSM.pdf
Size:
18.01 MB
Format:
Adobe Portable Document Format