EL REPOSITORIO SE ENCUENTRA EN MARCHA BLANCA

 

Thesis
ANÁLISIS Y EVALUACIÓN DE MÉTODOS UTILIZADOS PARA LA DETECCIÓN DE ISLA EN SISTEMAS DE GENERACIÓN FOTOVOLTAICA

dc.contributor.advisorKOURO RENAER, SAMIR FELIPE
dc.contributor.authorCOLLAO VÁSQUEZ, ÁLVARO IGNACIO
dc.contributor.departmentUniversidad Tecnica Federico Santa Maria UTFSM ELECTRONICAes_CL
dc.contributor.otherROJAS MONRROY, CHRISTIAN ALEXIS
dc.coverage.spatialUniversidad Técnica Federico Santa María UTFSM. Casa Central Valparaísoes_CL
dc.creatorCOLLAO VÁSQUEZ, ÁLVARO IGNACIO
dc.date.accessioned2024-10-29T22:50:47Z
dc.date.available2024-10-29T22:50:47Z
dc.date.issued2016
dc.descriptionCatalogado desde la version PDF de la tesis.es_CL
dc.description.abstractDENTRO de toda la gama existente de convertidores de corriente continua a corrientealterna, tambien conocidos en la literatura electronica como inversores, existen unoscapaces de inyectar energa en sincrona con una red de referencia, que comunmente es lared de suministro electrico, estos inversores son muy utilizados en el campo fotovoltaico yse conocen como inversores On-Grid. La interconexion entre el inversor, la carga y la redelectrica da lugar a multiples problemas, tales como la distorsion de armonicos, regulacionde voltaje, anti-islanding, interrupciones sostenidas, entre otras.El desarrollo de esta memoria hara enfasis al estudio del fenomeno isla, uno de losproblemas de interconexion mencionados anteriormente. Este fenomeno se produce cuandola energa suministrada por la red electrica es interrumpida y el generador fotovoltaicocontinua energizando una parte, o la totalidad, de la carga. Entonces, el inversor ya no seencuentra en sincrona con la red electrica y esta deja de controlar esa fraccion aislada delsistema; comprometiendo la seguridad, el restablecimiento de la red y la con abilidad delequipo [1]. Para evitar el fenomeno islanding existen multiples metodos de control que soncapaces de determinar la inexistencia de la red electrica. El objetivo es analizar y evaluarcada uno de estos metodos; para ello se debera; inicialmente, modelar y simular el inversorcon inyeccion a la red para posteriormente modelar y simular cada metodo de deteccioncon el n de generar tablas y gra cas comparativas que ayuden a determinar las ventajas ydesventajas de cada metodo. Seran evaluados parametros de tiempo de deteccion, armonicosde corriente y la zona de no deteccion, y se trabajara en base a las normas establecidas porel estandar IEEE 929-2000 (IEEE Std. 929; 2000).es_CL
dc.description.abstractINSIDE the range of existing converters of direct current to altern current, also knownin the electronic literature as inverter, there are some of it capable of inyecting energyaccording to a reference network that is usually the electricity grid. These inverters arevery common and widely used in the photovoltaic eld and they are known as On Gridinverters. The interconnection between the inverter, load and the grid circuit resultsin a multiple problem: harmonic distortion, voltage regulation, anti-islading, sustaineddisruptions, between others.The development of this nal project will emphasize the study of island phenomenon, oneof the interconnection problems mentionated before. This phenomenon is produced whenthe power supplied by the mains is interrupted and the photovoltaic generator continuesenergizing a part, or the entire load [1]. So, the inverter is no longer in synchronized withthe grid and the mains stops controlling this isolated fraction of the system; compromisingsafety, restoration of the network and the equipment reliability.To avoid the islanding phenomenon there are several control methods capable ofdetermining the existence of the grid. The objective is to analyze and evaluate each of thesemethods; for that it will be required, initially, to model and simulate the grid-tied inverter;later on, it will be possible to model and simulate each detection method in order to generatecomparative graphs and tables that help to determine the advantages and disadvantages ofeach method. some parameteres as detection time, current harmonics and the non detectionzone will be evaluated. The study is based on the standards established by the standardIEEE 929-2000 (IEEE Std. 929; 2000).eng
dc.description.degreeIngeniería Civil Electrónicaes_CL
dc.format.mediumCD ROM
dc.identifier.barcode3560900257625
dc.identifier.urihttps://repositorio.usm.cl/handle/123456789/54870
dc.rights.accessRightsB - Solamente disponible para consulta en sala (opción por defecto)
dc.subjectANTI-ISLANDINGes_CL
dc.subjectINVERSORes_CL
dc.subjectMETODOS DE CONTROLes_CL
dc.subjectZONA DE NO DETECCIONes_CL
dc.titleANÁLISIS Y EVALUACIÓN DE MÉTODOS UTILIZADOS PARA LA DETECCIÓN DE ISLA EN SISTEMAS DE GENERACIÓN FOTOVOLTAICAes_CL
dc.typeTesis de Pregradoes_CL
dspace.entity.typeTesis
usm.date.thesisregistration2016
usm.identifier.thesis4500012593

Files

Original bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
3560900257625UTFSM.pdf
Size:
5.29 MB
Format:
Adobe Portable Document Format