Thesis Evaluación técnico económica del aprovechamiento de la geotermia de baja entalpía para la cogeneración utilizando un ciclo rankine orgánico
Loading...
Date
2014
Authors
Journal Title
Journal ISSN
Volume Title
Program
Magister en Economía Energética
Departament
Campus
Campus Casa Central Valparaíso
Abstract
El Objetivo del presente trabajo es evaluar la viabilidad técnica y económica de desarrollar un proyecto de cogeneración con ciclo Rankine Orgánico, que permita aprovechar la geotermia de baja a media entalpía (de 80ºC a 120ºC) en instalaciones hoteleras asociadas a fuentes termales. Se realizó en primer lugar una revisión del estado del arte, que permitió conocer los principales parámetros de operación de sistemas de las características estudiadas. Se encontraron casos de éxito de instalaciones de geotermia con ciclo Rankine orgánico, y particularmente casos de éxito de instalaciones de este tipo para la hotelería asociada a fuentes termales con fines curativos, utilizada para cubrir las demandas de energía eléctrica y calor. De los casos de éxito revisados se detectó que existen instalaciones en que se aprovechan fuentes termales de hasta un mínimo de 75ºC. Se revisaron los catastros de fuentes termales del país estableciendo así el conjunto de termas que presentan oportunidades de desarrollo de instalaciones de Ciclo Rankine Orgánico para la cogeneración. Adicionalmente, se han caracterizado las instalaciones turísticas asociadas a cada fuente termal, de modo de descartar aquellos casos que no presentan instalaciones hoteleras, y por lo tanto no tienen mayores demandas de energía. Se encontraron 6 fuentes termales asociadas a hotelería que cuentan con reservorios con temperaturas mayores a los 75 ºC, y que por lo tanto presentan oportunidades de desarrollo de la tecnología estudiada(...).
The main goal of the current project is to determine de technical and economical feasibility of cogeneration with Organic Rankine Cycle with low to moderate enthalpy (80ºC to 120ºC) geothermal resources, in the hotel sector associated with hot springs. A state of the art review was conducted, that allowed to know the main operating parameters for systems involving the studied characteristics. Successful cases of geothermal installations with organic Rankine cycle were found, including specific cases of hotels using hot springs as energy resource, for heat and power demand. Among these cases some of the installations were found using geothermal resources from a minimal value of 75ºC. The hot springs cadaster was examined to identify the group of hot springs which have chances of developing for ORC systems. Furthermore, the tourist facilities associated to each hot spring were characterized, dismissing those cases where there are no hotel facilities available (which would mean no energy demand). 6 hot springs were found associated with hotel facilities and with geothermal resources higher than 75ºC, therefore with chances of development for the studied technology(...).
The main goal of the current project is to determine de technical and economical feasibility of cogeneration with Organic Rankine Cycle with low to moderate enthalpy (80ºC to 120ºC) geothermal resources, in the hotel sector associated with hot springs. A state of the art review was conducted, that allowed to know the main operating parameters for systems involving the studied characteristics. Successful cases of geothermal installations with organic Rankine cycle were found, including specific cases of hotels using hot springs as energy resource, for heat and power demand. Among these cases some of the installations were found using geothermal resources from a minimal value of 75ºC. The hot springs cadaster was examined to identify the group of hot springs which have chances of developing for ORC systems. Furthermore, the tourist facilities associated to each hot spring were characterized, dismissing those cases where there are no hotel facilities available (which would mean no energy demand). 6 hot springs were found associated with hotel facilities and with geothermal resources higher than 75ºC, therefore with chances of development for the studied technology(...).
Description
Catalogado desde la versión PDF de la tesis
Keywords
Eficiencia energética, Fuentes termales