Evaluación técnico-económica para disminución de pérdidas por medio de eliminación de armónicos en red de distribución eléctrica

dc.contributor.advisorBarrueto Guzman, Aldo Enrique (Profesor Guía)
dc.contributor.advisorValdivia Lefort, Patricio (Profesor Guía)
dc.contributor.authorCastillo Molina, Pablo Andrés
dc.contributor.departmentUniversidad Técnica Federico Santa María. Departamento de Ingeniería Eléctricaes_CL
dc.contributor.otherCANCINO LOBOS, DENISSE
dc.coverage.spatialCampus San Joaquín, Santiagoes_CL
dc.date.accessioned2024-10-31T10:43:33Z
dc.date.available2024-10-31T10:43:33Z
dc.date.issued2020-02
dc.description.abstractFrente a las nuevas exigencias de calidad y seguridad de servicio en sistemas eléctricos de distribución, impuestas por la nueva norma técnica, se debe tener un mayor control y medición sobre varios fenómenos eléctricos tales como el Flicker, la continuidad de suministro eléctrico, contaminación armónica, entre otros. En particular esta memoria hace énfasis en el fenómeno de la contaminación armónica dentro de las redes de distribución. Esta memoria se enfocó en analizar, en función de las mediciones existentes, el comportamiento del contenido armónico de las redes de media tensión y los transformadores de distribución, para determinar porcentajes de pérdidas de energía en una empresa de distribución eléctrica específica en Chile. Lo anterior, debido a que la empresa distribuidora que solicitó el estudio tiene como objetivo primordial implementar soluciones que permitan reducir las pérdidas técnicas a causa de la contaminación armónica, y a su vez evaluar las mismas como una variable de entrada en el análisis económico. Adicionalmente, el análisis económico establece indicadores de inversión y tiempo de retorno de inversión necesario para cada equipo de la solución analizada, para media y baja tensión.es_CL
dc.description.abstractFaced with the new demands for quality and safety of service in electrical distribution systems, imposed by the new technical standard, it must have greater control and measurement on various electrical phenomena such as Flicker, the continuity of electricity supply, harmonic contamination, among others. In particular, this report emphasizes the phenomenon of harmonic contamination within distribution networks. This report focused on analysis, based on the measurements detected, the behaviorof the harmonic content of the voltage media networks and distribution transformers, to determine percentages of energy losses in a specific electricity distribution company in Chile. All of this, as a part of the request made by the distribution company, who’s main objective is to implement solutions that reduce technical losses created by harmonic contamination, and at the same time, evaluate these loses as an input variable in the economic analysis. In addition, the economic analysis establishes investment indicators and the necessary investment recovery time for each equipment of the analyzed solution, for medium and low voltage.es_CL
dc.description.degreeINGENIERO CIVIL ELECTRICISTAes_CL
dc.description.programUNIVERSIDAD TÉCNICA FEDERICO SANTA MARÍA UTFSM. DEPARTAMENTO DE INGENIERÍA ELÉCTRICA. INGENIERÍA CIVIL ELÉCTRICAes_CL
dc.identifier.barcode3560902038945es_CL
dc.identifier.urihttps://repositorio.usm.cl/handle/123456789/65559
dc.subjectContaminación Armónicaes_CL
dc.subjectRedes Eléctricases_CL
dc.subjectEmpresas Eléctricases_CL
dc.subject.otherINGENIERIA CIVIL ELECTRICAes_CL