EL REPOSITORIO SE ENCUENTRA EN MARCHA BLANCA

 

Thesis
CARACTERIZACIÓN DEL HORMIGÓN REFORZADO CON FIBRAS SINTÉTICAS ESTRUCTURALES MEDIANTE ENSAYO EN 14651

dc.contributor.advisorCARMONA MALATESTA, SERGIO
dc.contributor.authorPEREIRA CHAMORRO, CARLOS ENRIQUE
dc.contributor.departmentUniversidad Tecnica Federico Santa Maria UTFSM OBRAS CIVILESes_CL
dc.coverage.spatialUniversidad Técnica Federico Santa María UTFSM. Casa Central Valparaísoes_CL
dc.date.accessioned2024-10-31T13:44:07Z
dc.date.available2024-10-31T13:44:07Z
dc.date.issued2016
dc.descriptionCatalogado desde la version PDF de la tesis.es_CL
dc.description.abstractDentro de las últimas décadas, se han incrementado los estudios de hormigones con fibra, desarrollándose distintas fibras, de variadas propiedades y características. Tomando especial relevancia el estado post fisuración que se produce en los hormigones una vez aplicada la carga.Considerando lo descrito anteriormente, se procedió a utilizar ensayos de flexo tracción, siendo el más óptimo para este tipo de hormigones, representando de mejor forma las condiciones de carga a la que será sometido, para ello se ha utilizado la norma europea EN- 14651, la que se adapta a este tipo de ensayos. El enfoque de esta memoria es comparar las diferentes resistencias residuales obtenidas, con dosificaciones de 5 y 8 kg/m3 de fibra respectivamente, de tal manera, que obteniendo su desplazamiento, se analiza el comportamiento de la grieta producida, procediendo a comparar su valor real obtenido con el teórico calculado.Además analizar las probetas con el límite de proporcionalidad de cada dosificación utilizada, a fin de determinar si corresponde a fibra estructural o fibra no estructural, mediante parámetros establecidos previamente.La principal característica de este tipo de hormigones, es que una vez agregada la fibra sintética (Barchip 48), cambia su capacidad de soporte en el peak de su resistencia, es decir, en vez de tener una falla frágil, se comporta como un elemento dúctil, aumentando considerablemente su desplazamiento y tenacidad al agregar fibras. Además se debe considerar que mientras más fibra se agrega, disminuye la capacidad de resistencia a la compresión, por ello se deben equilibrar estos puntos.Finalizado los ensayos, se procederá a comparar de forma gráfica los resultados para las distintas dosificaciones, carga vs desplazamiento, tamaño de la grieta real y teórico, en conjunto con la resistencia residual a la flexión en tracción y su CMOD.es_CL
dc.description.abstractIn last decades, the concrete with synthetics fibers has increased, developing different fibers, with different properties and characteristics. The state of post cracking that occur to the concrete with synthetics fibers is the most important variable.Considering the last words, we proceed to use tensile test, it is the better test for this kind of concrete and also represent the conditions of strength, and we use the European statement EN- 14651 adapted for this kind of test. The approach of this work is to compare the different residual resistance of all the joists, with dosage of 5 and 8 kg/m3 of fibers, so with the results of displacements, we can analyze the behavior of the crack of the joist, and then we compare the real and the theorist values.Furthermore we analyze the joists to know the LOP (limit of proportionality), for the purpose of define if the joist is structural or not.The main characteristic of this kind of concrete is that after add the synthetic fiber (Barchip 48), increase the peak of resistance, that is to say, instead of get a fragile failure it become a ductile material that increase the tenacity and displacement of the break when we add fibers. Besides when the number of fibers enhance, the compression resistance decreases the compressive strength.When test ends, we compare with graphics the results of the entire joist, strength vs displacement, size of real break and theory break and the residual strength and the CMOD.eng
dc.description.degreeCONSTRUCTOR CIVILes_CL
dc.description.programCONSTRUCCIÓN CIVIL
dc.format.mediumCD ROM
dc.identifier.barcode3560900232481
dc.identifier.urihttps://repositorio.usm.cl/handle/123456789/66245
dc.rights.accessRightsB - Solamente disponible para consulta en sala (opción por defecto)
dc.subjectENSAYO EN 14651es_CL
dc.subjectENSAYOS DE FLEXO TRACCIONes_CL
dc.subjectFIBRAS SINTETICAS ESTRUCTURALESes_CL
dc.subjectHORMIGONES CON FIBRAes_CL
dc.titleCARACTERIZACIÓN DEL HORMIGÓN REFORZADO CON FIBRAS SINTÉTICAS ESTRUCTURALES MEDIANTE ENSAYO EN 14651es_CL
dc.typeTesis de Pregradoes_CL
dspace.entity.typeTesis
usm.date.thesisregistration2016
usm.identifier.thesis4500012727

Files

Original bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
3560900232481UTFSM.pdf
Size:
1.5 MB
Format:
Adobe Portable Document Format