EVALUACIÓN TÉCNICO-ECONÓMICA PARA DISMINUCIÓN DE PÉRDIDAS POR MEDIO DE ELIMINACIÓN DE ARMÓNICOS EN RED DE DISTRIBUCIÓN ELÉCTRICA

Thumbnail
View/Open
3560902038945UTFSM.pdf (1.167Mb)
Date
2020-02
Author
CASTILLO MOLINA, PABLO ANDRÉS
Metadata
Show full item record
Abstract
Frente a las nuevas exigencias de calidad y seguridad de servicio en sistemas eléctricos de distribución, impuestas por la nueva norma técnica, se debe tener un mayor control y medición sobre varios fenómenos eléctricos tales como el Flicker, la continuidad de suministro eléctrico, contaminación armónica, entre otros. En particular esta memoria hace énfasis en el fenómeno de la contaminación armónica dentro de las redes de distribución. Esta memoria se enfocó en analizar, en función de las mediciones existentes, el comportamiento del contenido armónico de las redes de media tensión y los transformadores de distribución, para determinar porcentajes de pérdidas de energía en una empresa de distribución eléctrica específica en Chile. Lo anterior, debido a que la empresa distribuidora que solicitó el estudio tiene como objetivo primordial implementar soluciones que permitan reducir las pérdidas técnicas a causa de la contaminación armónica, y a su vez evaluar las mismas como una variable de entrada en el análisis económico. Adicionalmente, el análisis económico establece indicadores de inversión y tiempo de retorno de inversión necesario para cada equipo de la solución analizada, para media y baja tensión.
 
Faced with the new demands for quality and safety of service in electrical distribution systems, imposed by the new technical standard, it must have greater control and measurement on various electrical phenomena such as Flicker, the continuity of electricity supply, harmonic contamination, among others. In particular, this report emphasizes the phenomenon of harmonic contamination within distribution networks. This report focused on analysis, based on the measurements detected, the behaviorof the harmonic content of the voltage media networks and distribution transformers, to determine percentages of energy losses in a specific electricity distribution company in Chile. All of this, as a part of the request made by the distribution company, who’s main objective is to implement solutions that reduce technical losses created by harmonic contamination, and at the same time, evaluate these loses as an input variable in the economic analysis. In addition, the economic analysis establishes investment indicators and the necessary investment recovery time for each equipment of the analyzed solution, for medium and low voltage.
 
URI
https://hdl.handle.net/11673/48800
Collections
  • TESIS de Pregrado de acceso ABIERTO

© Universidad Técnica Federico Santa María
Avenida España 1680, Edificio U, Valparaíso· 56-32-2654147, Informaciones escribir a email repositorio@usm.cl Repositorio Digital administrado por el Área de Archivo Digital, Dirección de Información y Documentación Bibliográfica Institucional

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV


USM
 

 

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsAdvisorProgramOther AdvisorThis CollectionBy Issue DateAuthorsTitlesSubjectsAdvisorProgramOther Advisor

My Account

Login

© Universidad Técnica Federico Santa María
Avenida España 1680, Edificio U, Valparaíso· 56-32-2654147, Informaciones escribir a email repositorio@usm.cl Repositorio Digital administrado por el Área de Archivo Digital, Dirección de Información y Documentación Bibliográfica Institucional

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV


USM