DESARROLLO, DISEÑO Y EVALUACIÓN DE PEQUEÑOS MEDIOS DE GENERACIÓN DISTRIBUIDA (PMGD) FOTOVOLTAICA Y SU IMPACTO EN LA RED ELÉCTRICA SEGÚN MARCO REGULATORIO VIGENTE

Thumbnail
View/Open
3560900258155UTFSM.pdf (7.225Mb)
Date
2018
Author
CHELECH GONZALEZ, OMAR ANIBAL
Metadata
Show full item record
Abstract
En el presente trabajo de titulación se efectuaron todos los estudios necesarios para el diseño del proyecto Atocha, que corresponde a una PMGD de 3 MW de potencia instalada.Los estudios e informes de impacto pertinentes se realizaron en base a la Norma Técnica de Operación y Conexión de PMGD en Media Tensión y, en adición, se consideraron estudios extra como cálculo de pérdidas en el sistema y efecto de capacitancias parásitas, resultando en una evaluación positiva de la viabilidad de la conexión de la generadora, siempre y cuando se conecta además un reactor de compensación.Finalmente se evaluó la proyección económica, tanto para elegir los equipos de paneles e inversores a usar, como de la obra en su totalidad. Al desconocerse la estabilización de precio de venta de energía eléctrica se usó como referencia el precio nudo de energía referido a la línea Quillota 220, desde donde se abastece el alimentador de distribución.Se obtienen pronósticos positivos en cuanto a la rentabilidad del proyecto y se adjunta un análisis F.O.D.A. para resumir aspectos internos y externos que afectan en forma positiva o negativa la conexión del PMGD.
 
In the following work for college degree were made necessary studies for the design of the Atocha’s Project, which is a PMGD of 3 MW of power installed.The studies and reports of impact were made based on the Techical Norm of Operation and Connection of PMGD in Medium Voltage plus were considerated extra studies such as calculation of losses in the system and effect of parasyte capacitances, resulting a positive evaluation of the viability of the generation center’s connection, as long as a reactor is also connected.Finally an economical projection was evaluated, for both to chose the equipments of PV modules and inverters as well as the complete oeuvre. As the stabilization of selling price of electric energy it was used the node price refered to Quillota 220 line as reference, where from the feeder is energized.Obtained a positive pronostic about the rentability of the project and is added a S.W.O.T. analysis to resume the inner and outer aspects that affect in a positive or negative war the connection of the PMGD.
 
URI
http://hdl.handle.net/11673/24054
Collections
  • TESIS de Pregrado de acceso ABIERTO

© Universidad Técnica Federico Santa María
Avenida España 1680, Edificio U, Valparaíso· 56-32-2654147, Informaciones escribir a email repositorio@usm.cl Repositorio Digital administrado por el Área de Archivo Digital, Dirección de Información y Documentación Bibliográfica Institucional

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV


USM
 

 

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsAdvisorProgramOther AdvisorThis CollectionBy Issue DateAuthorsTitlesSubjectsAdvisorProgramOther Advisor

My Account

Login

© Universidad Técnica Federico Santa María
Avenida España 1680, Edificio U, Valparaíso· 56-32-2654147, Informaciones escribir a email repositorio@usm.cl Repositorio Digital administrado por el Área de Archivo Digital, Dirección de Información y Documentación Bibliográfica Institucional

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV


USM